Updating video analytics packages

Video analytics is installed as a set: flussonic-vision ties vision-inference and vision-identification to the same version, while vision-models contains models. Keep services and models compatible when updating.

Update video analytics

Before updating, preserve /etc/vision/ and record installed versions:

dpkg-query -W flussonic-vision vision-inference vision-identification vision-models vision-runtimes vision-python

Use the configured stable Flussonic package repository. If it is not configured, follow the repository step in Watcher installation.

Update the index and inspect planned versions:

apt update
apt-cache policy flussonic-vision vision-inference vision-identification vision-models
apt-get -s install flussonic-vision

Install the update and restart services:

apt install flussonic-vision
systemctl restart vision-inference vision-identification
systemctl status vision-inference vision-identification

After startup, check logs and analytics node state in Watcher:

journalctl -u vision-inference -u vision-identification -n 100 --no-pager

Confirm new episodes appear from a test camera. A running service alone does not confirm detection or identification works.

Select a version and roll back

List available versions:

apt-cache madison flussonic-vision vision-inference vision-identification vision-models

To install a particular release, specify the linked service versions and separately choose a compatible available model version from apt-cache. Model and service versions need not match. Inference 26.11 recommends vision-models 26.08 or later; this dependency lower bound still requires verification for the selected algorithm and device.

Check the installation plan for services 26.11 and the selected model version:

MODELS_VERSION='<available compatible model version>'
apt-get -s install flussonic-vision=26.11 vision-inference=26.11 vision-identification=26.11 "vision-models=$MODELS_VERSION"

After checking, run the same request without -s. Record model versions separately from service versions. Before upgrading an accelerator, check the computation option and runtime.

Before returning to an earlier release, check the selected set's dependencies with apt-get -s. Do not downgrade only the flussonic-vision metapackage: services and models must remain compatible. Older releases could use separate model packages per accelerator; 26.11 uses a single vision-models.

If a service does not start after an update, save the log, compare configuration with .example files and contact support with package and hardware versions.