Updating video analytics packages¶
Video analytics is installed as a set: flussonic-vision ties vision-inference and vision-identification to the same version, while vision-models contains models. Keep services and models compatible when updating.
Update video analytics¶
Before updating, preserve /etc/vision/ and record installed versions:
dpkg-query -W flussonic-vision vision-inference vision-identification vision-models vision-runtimes vision-python
Use the configured stable Flussonic package repository. If it is not configured, follow the repository step in Watcher installation.
Update the index and inspect planned versions:
apt update
apt-cache policy flussonic-vision vision-inference vision-identification vision-models
apt-get -s install flussonic-vision
Install the update and restart services:
apt install flussonic-vision
systemctl restart vision-inference vision-identification
systemctl status vision-inference vision-identification
After startup, check logs and analytics node state in Watcher:
journalctl -u vision-inference -u vision-identification -n 100 --no-pager
Confirm new episodes appear from a test camera. A running service alone does not confirm detection or identification works.
Select a version and roll back¶
List available versions:
apt-cache madison flussonic-vision vision-inference vision-identification vision-models
To install a particular release, specify the linked service versions and separately choose a compatible available model version from apt-cache. Model and service versions need not match. Inference 26.11 recommends vision-models 26.08 or later; this dependency lower bound still requires verification for the selected algorithm and device.
Check the installation plan for services 26.11 and the selected model version:
MODELS_VERSION='<available compatible model version>'
apt-get -s install flussonic-vision=26.11 vision-inference=26.11 vision-identification=26.11 "vision-models=$MODELS_VERSION"
After checking, run the same request without -s. Record model versions separately from service versions. Before upgrading an accelerator, check the computation option and runtime.
Before returning to an earlier release, check the selected set's dependencies with apt-get -s. Do not downgrade only the flussonic-vision metapackage: services and models must remain compatible. Older releases could use separate model packages per accelerator; 26.11 uses a single vision-models.
If a service does not start after an update, save the log, compare configuration with .example files and contact support with package and hardware versions.